Swing gate

Hengshun An Technology


Shenzhen Hengshun An Technology Co., Ltd.
Shenzhenshiheng Shun Technology Co., Ltd
Foreword
respected user:
Thank you very much for purchasing the channel gate product developed and produced by Shenzhen Hengshun An Technology Co., Ltd. This series of channel gate products adopts our company's unique technology, and the equipment adopts standard electrical interfaces externally. It can be easily integrated with magnetic card, barcode card, ID card and IC card reading and writing devices, and can be widely used in hotels, factories and mines. Communities, clubs, clubs, enterprises and institutions need to implement intelligent management of the channel.
The channel gate you purchased is developed and produced in accordance with the requirements of the quality management system. It is a product that has passed strict and careful inspection.
This product is a technically strong device. In order to ensure its safe and reliable operation, in this manual, special attention has been given to the matters that should be paid attention to during the operation of the system. Please use the product you have purchased. Before you read this manual carefully, you will not damage your rights due to improper operation.
table of Contents
一、Introduction to Equipment····························································································· ······· 4
1.1 Brief Description································································································· ················ 4
1.2 Features······························································································· ·· 4
1.3 Main Technical Parameters······························································································· 4
Second, the outline size ······························································································· ······· 5
2.1 Device Dimensions···························································································· 5
Third, product structure and common working principle ···························································································· 8
3.1 Channel gate mechanical system·····························································································
3.2 Channel gate control system······························································································· 8
3.3 System Working Principles······························································································· 8
Fourth, equipment installation and commissioning··························································································· ··· 9
4.1 Equipment Installation································································································· ··· 9
4.2 Device Function Tuning······························································································· 10
V. Common Faults and Routine Maintenance of Channel Gates····································································
Six, equipment operation instructions ································································································· ···· 13
1, equipment introduction
1.1 Brief description
Channel gate is the intelligent channel management equipment that our company has developed and produced for many years. The device integrates mechanical, electronic, microprocessor control and various reading and writing technologies organically. Through the configuration of a variety of different reading and writing equipment, the use of reliable performance safety protection devices and real-time alarm system and direction indication interface, jointly coordinate the realization of intelligent control and management of the channel.
The shape of the equipment is stamped and formed with stainless steel plate, which is beautiful in appearance, rustproof, and durable. It also uses standard electrical interfaces for external use. It can easily integrate card readers such as barcode cards, ID cards, and IC cards on the device to provide access to personnel. A civilized and orderly way of access can also eliminate the entry of illegal personnel. In addition, the system has also specifically designed functions to meet the requirements of fire protection. In the event of an emergency, it ensures unimpeded access and facilitates timely evacuation.
1.2. Features
1) It has zero self-check function, which is convenient for user maintenance and use;
2) illegal entry into the alarm prompts;
3) Anti-knocking function, when no opening signal is received, the telescopic baffle (swing arm) is automatically locked;
4) Infrared/mechanical double anti-clamping function, the motor will automatically stop working within a specified time when the resistance of the retractable baffle (swing arm) is reset, and the intensity is very small, and an alarm signal is issued at the same time;
5) With automatic reset function, after the pedestrian reads the valid card, if the system does not pass within the specified time, the system will automatically cancel the pedestrian's access right;
6) The unified standard external electrical interface can be connected with a variety of readers, and can be remotely controlled and managed through a management computer;
7) The entire system runs smoothly and with little noise;
1.3 Main technical parameters
1) Power supply voltage: AC220±10% V, 50HZ
2) Drive motor: DC motor 24V/100W
3) Working environment temperature: -15OC - 60 OC
4) Relative humidity: Relative humidity ≤90%, no condensation
5) Input interface: 12V level signal or 12V pulse signal driving current >10mA with pulse width >100ms
6) Communication Interface: RS485 Electrical Standard,
7) Communication distance: ≤1200 meters
8) Channel Width: Gate 600mm Single Gate 600-900MM
9) Speed: 30 persons/minute (normally open mode), 20 persons/minute (normally closed mode)
10) Gate opening and closing time: 1 second stop, 2-3 seconds swing gate
2 Product Dimensions
2.1 device dimensions
Blocking device external dimensions refer to the figure; (Note: the channel gate size is the same as the gate)


Bridge Type Corner Wedge Gate Bridge Type Angle Wagon Gate
1200x280x1000 1200x280x1000


Long swing gate Vertical swing gate
1600x280x1050 280x280x1000
Cylindrical swing gate Bridge type round corner gate
¢168x1050 1400x300x1000


Bridge type angle gate Bridge type arc type gate
1200x300x1000 1200x300x1000


Vertical stop
600x300x1000
3. Product structure and working principle
3.1 Channel gate mechanical system
The channel gate mechanical system is divided into two parts: the chassis and the movement. As a carrier, the chassis is equipped with a direction indicator, a reading and writing device, an infrared sensor, etc. The main components of the movement include a motor, a frame, a transmission shaft, a gate, and the like;

7
3. 2-channel gate electronic control system

Electronic control system consists of card reader, main control board, infrared sensor, direction indicator, alarm, limit switch, transformer and other components.
Card reader (self-provided): After reading the information on the card and processing it by judgment, it sends an application pass signal (switch signal) to the main control board;
® Main Control Board: The system's control center, which receives signals from readers and infrared sensors, performs logic judgments and processing on these signals, and then issues commands to direction indicators, motors, counters, and alarms.
® Infrared Sensors: Detects pedestrian locations and provides security protection;
® Direction indicator: displays the current pass status of the channel and guides pedestrians through the channel in a safe and orderly manner;
® Alarm: When the system detects a pedestrian who entered the channel illegally, an alarm message is issued.
® limit switch: control the position of the gate rotation;
3.3 System Working Principle
1) Turn on the power and the system will enter the working state after 3 seconds.
2) When the card reader reads a valid card, the beeper will emit a sweet sound and prompt the pedestrian to read the card successfully. At the same time, the information read from the card will be judged and processed, and the application signal will be sent to the main control board. ;
3) The main control board receives the signals of the card reader and infrared sensor, and after comprehensive processing, it sends an effective control signal to the direction indicator and the motor to turn the direction indicator into the green arrow access indicator. If the system is in normal condition, In closed mode, the motor runs and the limit switch controls the power
Motor-turning angle, gate open (in the normally open mode, the motor does not move), allowing pedestrians to pass;
4) After the pedestrian indicates the passage through the direction indicator sign, the infrared sensor senses pedestrian access.
Pass the entire process of the channel, and continue to send signals to the main control board until the pedestrian has completely passed the channel;
5) If the pedestrian forgets to read the card or read the invalid card to enter the channel, the system will prohibit pedestrians (for the normally open mode, the gate will be closed; normally closed mode, the gate will not move;), and an alarm will be issued until the pedestrian exits the channel. Only when the alarm is released; read the valid card again to allow the passage;
4. Equipment installation and debugging
4.1 Equipment Installation
u Ready to install equipment tools and inventory parts according to the packing list;
u After clarifying the system composition and working methods, conduct overall planning and prepare to start installation;
u After installing the foundation surface of the equipment properly, put the equipment in order;
u After setting the hole position, drill a hole and embed M12 anchor bolt or expansion bolt;
u Put strong and weak cables respectively in 3/4′′ PVC pipe and bury it in the corresponding position with cement;
u Move each chassis to the corresponding installation position and align the anchor bolts one by one.
u Check whether the system composition and working methods are correct. After the inspection is correct, proceed to the next step;
u Open the door of the chassis and select one of the devices as a reference.
Reference datum) Align the bolt hole of the machine frame with the corresponding anchor bolt and tighten the nut first;
u Open the door of an adjacent chassis, align the bolt holes of the stand with the anchor bolts and align the predetermined reference devices, and tighten the nuts; if there are multiple units, install them and so on;
u Referring to the wiring diagram, connect the power line and control line and connect the system protection ground.
u After the state inspection and function debugging are qualified, tighten the groundnut again;
! caveat:

1. The depth of the buried PVC pipe should be greater than 60mm, the height of the exposed ground should be greater than 50mm, and the outlet should be turned back to prevent the pipe from entering the water.
2. When installing channel gates, the left and right gates of each channel should be aligned;
3. Connect the system protection ground wire;
4. If the equipment is used outdoors, a cement platform with a height of 100-200mm should be built at the installation site to prevent tides, and sun protection and rain protection facilities such as roofs should be added.
5. After the equipment is installed, the status inspection and function debugging are qualified before being put into normal use.
4.2 Device Function Commissioning
After the device status check is normal, the following function debugging can be performed!
Swing gate (brake) commissioning instructions
1 Preparation before commissioning
Check the mains connection according to the wiring diagram. Check the power wiring and other wiring of the entire device correctly. After confirming it is correct, it can be debugged on power-up!
The protective ground of the equipment must be reliably grounded, otherwise it is not allowed to use.
2 hardware configuration
Two-way swing gates (block gates) are double eyes, and one-way swing gates (block gates) are single eyes.
System parameter setting operation instructions
A general description
1. The display screen refers to the 3-digit LED displayed from left to right on the main control board;
2. The three keys from left to right are the INC key, the SET key, the DEC key, and the SET key for entering and exiting.
Menu or enter and exit function settings; INC key is used to add 1 to the parameters that need to be set; DEC key is used to decrement the parameters that need to be set;
Second, enter and exit menu settings
1. Enter the menu: press the SET button, after hearing a beep, release the SET button, then the display shows "P00", indicating that it has entered the menu setting state, then INC button and DEC button can be used To select the function number of the setting function; press the INC key, the function number is incremented by 1, and the DEC key function number is decremented by 1; there are 15 function settings, which are:
P00: Exit menu setting function. When P00 appears, press SET button to exit menu setting;
P01: Running direction when the motor is powered on, =000: Forward rotation when powered on, and reversed when =001 is powered on. (factory is 001)
P02: The longest running time of the gate, the unit is 0.1 seconds. If this time is set to 60, ie, 6 seconds, the gate will stop closing after the 6 seconds of closing has not been closed (the system default value is 60).
P03: Pedestrian travel time, unit seconds. If this time is set to 10, it will be 10 seconds. If the pedestrian does not pass the card within the set time, the card will be cancelled. (System default is 10)
P04: Working Mode (System Default is 000)
=000: two-way card
=001: Into the credit card, out of freedom
=002: Into the freedom, out of credit card
=003: Into freedom, out of freedom
=004: Forward opening (one-way)
=005: Exit gate (one-way)
P05: Inward opening speed: The speed from the closing position to the opening position of the gate. (System default is 10)
P06: Inward closing speed: The speed at which the gate will open from position to position and close to position. (System default is 10)
P07: Door opening speed: The speed of the door from closing position to opening position. (System default is 10)
P08: Door closing speed: The speed of the door from opening to closing to closing. (System default is 10)
P09: Pedestrians pass time is considered to be one person within the set time (system default is 10)
P10: The inward direction counter is cleared. When the P10 key is pressed, C-L is displayed after the SET key is pressed. After the INC key is pressed, the system sends a counter clearing signal to the system and the inward counter is cleared.
P11: When the output counter is cleared, when the P11 key is pressed, C-L is displayed after the SET key is pressed. After the INC key is pressed, the system sends a clear signal to the counter and the output counter is cleared.
P12: With or without memory settings (system default is 000)
=000: bidirectional with memory,
= 001: Incoming without memory, outgoing with memory.
= 002: Inward with memory, out without memory.
=003: Two-way without memory.
P13: equipment communication address, that is a few machines. Range 1-255. (System default is 001)
P14: Device Type
=000: The device is a swing gate
=001: device is a gate
P15: The system restores the default value. When P is displayed, press the SET key to display P-2. Press INC at this time
The key system restores the default value.
P16: The direction of opening the door is adjusted when the communication is opened. When =0, it goes in one direction, and when it is =1, it goes in the opposite direction. If the swing gate is set to 0, one side is set to ensure that the two gates of the same channel open in the same direction.
P17: How often the pedestrian delays after passing through the system. No delay is required when the gate is normal. If the gate
When it is longer, pedestrians will hit pedestrians immediately after they pass through to adjust the time delay to avoid them.
2. Exit the menu setting: Press the INC or DEC key. When the word P00 appears, press the SET key to exit the menu setting. (The lower the speed, the faster the speed.)
±

Notes: 1. No peripheral equipment may be added to the system without permission;
2. If the debugging result and the function are inconsistent during the debugging process, please refer to the Common Faults and Troubleshooting section.
5. Channel brake common fault handling and routine maintenance
5.1 After the card is swiped, the door is not opened, there is no response, or it does not open automatically after power off. Check again to see if the signal cable is dropped. Check whether the signal indicator on the main board has received the signal. .
5.2 The working direction of the direction indication is that the green arrow points left, right, or red cross. If the direction indicates no response, or the direction of the indication is incorrect. You can switch to another test and try it with a good one. Recheck the wiring
5.3 Channel gate has automatic opening function after power off. If it does not turn on after power off, the reason is that the voltage of backup battery (battery) inside is not enough, and there is no more than 10V of the voltage of multimeter.
After the 5.4 channel gate card is swiped, there is one open and one not open. Check again if the sync line is connected. After the connection is guaranteed, if the motherboard that does not open has received an open signal, if not, check whether the wiring is dropped or if the plug on the motherboard is plugged in.
5.5 After swiping, the gate opens, but the gate does not close. This situation is usually not good for the middle anti-clip infrared. Before fixing the chassis, it must be determined that the infrared pair is good enough to open and close the door normally. If there is no good infrared, after power on, it will alarm. After swiping, please use the direction arrow to exercise.
6. Equipment operation instructions
6.1 Before the equipment is put into use, it must be debugged through function; after normal debugging, it can be put into use;
6.2 It is forbidden to station people in the channel when the device is powered on;
6.3 When a pedestrian reads a cartoon, the sign of the direction indicator does not turn green and it is forbidden to enter the channel.
6.4 When pedestrians pass the passage, do not stay in the middle of the passage for a long time;
6.5 When passing through the gateway, do not be crowded and keep a certain distance between people.
6.6 Do not read the card and quickly pass through the gateway;
6.7 It is advisable to mark the passage of the machine at a conspicuous position in the work of the equipment, and guide the passers through the gate passage in a safe and orderly way;
6.8 The equipment should be properly managed when it is not working. It is forbidden to knock and shake the equipment.
6.9 When the equipment is in the closed state, it is forbidden to push or pull the gate;
! caveat:

1. Do not use this unit during lightning storms to prevent damage to the unit.
2. To ensure that the system protection is reliably connected to prevent personal injury;

Solar Garden Light