House inspection procedure

View two books and one list: House Quality Assurance Certificate; House Use Manual; Completion Acceptance Record Form; Area Actual Measurement Data in Contrast to the Area on the Purchase Contract (Self-measurable Set Area). The "Management Regulations for Quality Acceptance of Residential Projects by Households" requires developers to provide the "Resident Housing Quality Acceptance Checklist" when they submit homes to home buyers. The table must record in detail the appearance and size deviations, waterproofing, and hydropower of the houses in the home. The acceptance process, the existing problems, and the rectification of the eight items such as installation.
The main content of the acceptance inspection of residential construction projects includes the following: According to the requirements of the design drawings, on the basis of ensuring the safety and reliability of the foundation and main structure of the project, the quality of the perception of the house and the use of functional quality shall be checked.
After the acceptance of the household is qualified, the developer must issue a “Household Project Quality Acceptance Checklist” confirmed by the person in charge of the construction, construction, and supervision unit, and affix the construction quality of the construction, construction, and supervision units. Special chapter. If the quality of the residential project is not acceptable, the construction unit cannot organize the acceptance of the entire project.
Second, do not pay fees, no sign, prior inspection room: After finding the problem, you can't pay fees or sign it. Should first repair the house, at the same time to collect evidence, to lay the foundation for the future when necessary evidence (that is, through a tape recorder, video camera or camera to adjust the date record evidence), in particular, keep their own retention, home delivery representative signing of the house inspection problem record form. Checking the total area of ​​housing: over or under 3% of the total is very common (overpayment is less, less compensation is for the owner); the area within the suite is constant, and the pool area is increased more (real estate reduction, loss Is still the owner).
Third, the house is in good condition. When signing the owner's convention and pre-property management contract after handing over the keys, they are optimistic about the terms and cannot give up their rights.
Fourth, pay a reasonable fee (property management fee [should have Municipal Price Bureau approval], etc.)

Villa Design Residential House

Elevator Modernization

Elevator modernization (or lift modernisation) is the process of upgrading the critical parts of the elevator in order for it to be able to handle new technology, have better performance, improve safety, and even give the aesthetics an up-to-date appeal


Most elevators are built to provide about 20 years of service, as long as service intervals specified and periodic maintenance/inspections by the manufacturer are followed. As the elevator ages and equipment become increasingly difficult to find or replace, along with code changes and deteriorating ride performance, a complete overhaul of the elevator may be suggested to the building owners.

A typical modernization consists of controller equipment, electrical wiring and buttons, position indicators and direction arrows, hoist machines and motors (including door operators), and sometimes door hanger tracks. Rarely are car slings, rails, or other heavy structures changed. The cost of an elevator modernization can range greatly depending on which type of equipment is to be installed.

Modernization can greatly improve operational reliability by replacing mechanical relays and contacts with solid-state electronics. Ride quality can be improved by replacing motor-generator-based drive designs with Variable-Voltage, Variable Frequency (VVVF) drives, providing near-seamless acceleration and deceleration. Passenger safety is also improved by updating systems and equipment to conform to current codes.



Components needs to be replaced in different elevator modernization plan

Component Scheme of elevator modernization plan
Refurbishment work Partial modernization Full modernization Full replacement
Elevator car
Sling No No by building owners Yes
Door operator No by building owners Yes Yes
Cab design by building owners by building owners Yes Yes
Car doors by building owners by building owners Yes Yes
Car fixtures Yes by building owners Yes Yes
Wedges connected to the governor No No Yes Yes
Additional phone/intercom if they don't equipped by building owners Yes Yes Yes
Traveling cable No Yes Yes Yes
Hydraulic rams No No No Yes
Wire ropes No by building owners Yes Yes
Shaft
Counterweight No No No Yes
Guide rails No No No Yes
Buffers No No Yes Yes
Electrical components No No No Yes
Tapehead No Yes Yes Yes
Limit switches No Yes Yes Yes
Wiring No Yes Yes Yes
Compensations No No No Yes
Lobby
Shaft door components by building owners by building owners Yes Yes
Shaft doors by building owners by building owners by building owners Yes
Hall fixtures Yes by building owners Yes Yes
Machine room
Machines No by building owners Yes Yes
Controllers No Yes Yes Yes
Removal of the selector by building owners Yes Yes Yes
Overspeed governor No No Yes Yes
Additional unintended car movement protection device if they don't equipped by building owners by elevator safety code in countries
Backup battery or uninterruptible power supply No Yes Yes Yes




Benefits of elevator modernization

Modernization can greatly improve operational reliability by replacing mechanical relays and contacts with solid-state electronics. Ride quality can be improved by replacing motor-generator-based drive designs with Variable-Voltage, Variable Frequency (VVVF) drives, providing near-seamless acceleration and deceleration. Passenger safety is also improved by updating systems and equipment (such as double brake system, unintended car movement protection device on the brake system etc.) to conform to current codes.




With CEP traction elevator modernization, we use the existing elevator structure while upgrading the ride quality and reliability with state-of-the-art components. Upgrade to a CEP closed loop door operator or a sophisticated, energy saving VVVF inverter.

CEP traction elevator modernization can include:

  • CEP Microprocessor Based Control System
  • CEP Microprocessor Based Efficient Dispatch System
  • Energy Efficient AC Drives or SCR Drives on Existing AC Gearless Machines
  • Traction Machines (Geared / Gearless)
  • Rope Brake System
  • CEP Closed Loop Door Operating System
  • Car & Hall Pushbutton Fixtures & Indicators
  • Car & Counterweight Roller Guides
  • Seismic Upgrades
  • Security Upgrades
  • Cab Interior Renovations or Cab Replacement

NOTE: Complete tear-out modernizations are available.

Contact us TODAY for Right Modernization Package Available


OTIS Elevator Modernization, Thyssen Elevator Modernization, KONE Elevator Modernization, GiantKONE Elevator Modernization, ThyssenKrupp Elevator Modernization, Schindler Elevator Modernization, XJ Schindler Elevator Modernization, Xizi OTIS Elevator Modernization, Mitsubishi Elevator Modernization, Shanghai Mitsubishi Elevator Modernization, Fujitec Elevator Modernization, Hitachi Elevator Modernization, Toshiba Elevator Modernization, Hyundai Elevator Modernization, LG Elevator Modernization, Sigma Elevator Modernization, Express Elevator Modernization, GUANGRI Elevator Modernization, FUJI Elevator Modernization, BLT Elevator Modernization, CANNY Elevator Modernization, SJEC Elevator Modernization, KOYO Elevator Modernization, IFE Elevator Modernization

Elevator Modernization,Lift Modernisation,Passenger Lift Modernization,Passenger Elevator Modernization