Paint Brush,Paint Brush Online,Oil Brush Photoshop,Paint Tool Sai Brush Laizhou Chenke trading Co., Ltd. , https://www.chenkegroup.com
(1) The lightning protection design plan is detailed and accurate on the description of the surrounding environment, geographical features, geological conditions, climate and disastrous weather characteristics, and lightning activity rules of the proposed building. The nature of the proposed building, its importance, the building's building structure, height, floor area, layout, equipment layout, communication methods, etc. are described in a comprehensive manner. Then the selection of the lightning protection category based on the above description is correct.
(2) Whether the technical measures and construction techniques adopted in the design plan are based on the latest relevant technical standards or specifications.
(3) Whether the materials, specifications, and arrangements of the air-termination devices, lead-off wires in the external lightning protection devices meet the requirements, whether the structural column bars are used as much as possible, and how the utilization rate is; whether the calculation of the specific protection range of the lightning rods is correct or not. Whether or not the object is protected from side-impact lightning and pressure equalizing ring devices; the grounding device utilizes the steel reinforcement in the pile, ground beam, and platform, whether the material, specification and layout of the artificial grounding body are reasonable, and whether the grounding device has anti-step-voltage measures or not. Various electrical reserve terminals are provided.
(4) Whether the use of frame structures including the shear wall structure to strengthen the shielding effect in the internal lightning protection measures, and whether the selection of power surge protection devices, installation locations, and energy coordination of power lines, antenna feeder lines, transmission lines, and communication systems are reasonable, Whether there is a detailed description and drawing of the schematic diagram of the surge protection (lightning arrester) circuit and the schematic diagram of the arrester installation position, whether the method of total equipotential bonding and local equipotential bonding is in accordance with the National Building Standard Design Atlas “Equipotential Bonding Installation†The requirements for the equipotential bonding of metal bridges, metal pipes, and metal windows, railings, and metal components at specified heights are sufficient.
(5) Whether the power supply and distribution standard adopts the TN-CS or TN-S system as far as possible; whether the erection scheme of the high and low voltage power lines is introduced as far as possible and whether the buried length is long enough.
(6) Whether the integrated wiring meets the specification requirements.
(7) Whether related drawings and data are normative, comprehensive and easy to implement.
Lightning Protection Checkpoints
After a mine protection engineering design plan has been submitted to a unit that has the design qualification for lightning protection, it shall be strictly examined against relevant drawings. The main points are: