Introduction and Technical Parameters of DC Detection Table for Photovoltaic Power Plants

Photovoltaic plant DC detection table

Photovoltaic power plant DC detection table can directly replace conventional measuring instruments. It is an advanced intelligent and digital front-end acquisition component. The meter can have RS-485 communication interface and adopt Modbus-RTU protocol.

Photovoltaic power plant DC detection tables are designed for applications such as DC panels, solar power supplies, and telecommunications base stations. These meters measure current, voltage, power, and power in DC systems. Can be used for local display, but also with industrial control equipment, computer connections, form a measurement and control system.

Photovoltaic power plant DC detection table famous brands are Shanghai Ankerui PZ300-DI, PZ300-DV, PZ300-DUI, PZ300-DP, PZ300-DE.

The following takes the DC detection table of the PZ300-DE photovoltaic power station as an example to introduce the functions and technical parameters of the DC power meter of a photovoltaic power plant.

Applicable environment

l Operating temperature: LCD display: -10 °C ~ +45 °C; LED display: -10 °C ~ +55 °C

l Storage temperature: -20°C~+70°C

l Relative humidity: ≤93%RH, non-condensing, non-corrosive gas

l Altitude: ≤2500m

Electromagnetic Compatibility

l Static immunity test III (IEC61000-4-2)

l Radiation immunity test III (IEC61000-4-3)

l Electrical fast transient burst test IV (IEC61000-4-4)

l Surge immunity test IV (IEC61000-4-5)

l RF conducted interference test level III (IEC61000-4-6)

l Electromagnetic field immunity test III (IEC61000-4-8)

Technical Parameters

Current input

DC current 0~10A (direct input, starting current: 5mA)

0~9999A(external shunt or Hall element, programmable range)

Splitter support output 75mV

Hall device supports output 0~20mA, 4~20mA, 0~5V, 0~10V, etc.

Power consumption ≤ 1mW

Voltage input

DC voltage: 0~1000V

Input impedance ≥ 2kΩ/V

overload

1.2 times sustainable normal work, 2 times lasts 1 second

Accuracy level

Current, voltage: 0.5

Frequency: 0.05Hz

Active power, active energy: 0.5

Reactive power, reactive power: 1.0

Insulation resistance

≥100MΩ

Power frequency withstand voltage

3kV/1min(RMS) between power terminal group and signal input/output terminal group

Average time between failures

≥50000h

Electric energy

2 open-collector optocoupler pulses

Working power

Voltage range 85~265VAC, 50/60Hz, 110~350VDC, 36~48VDC

Power consumption ≤ 2W

Analog output

DC 4 to 20mA, DC 0 to 20mA (load <500Ω)

Call the police

1 relay output, 2A/30VDC or 2A/250VAC

Switch input

Dry contact input, instrument built-in power supply, optocoupler isolation

Switch output

Normally open relay passive contact, 1A/30VDC or 2A/250VAC

Optional function

C - with RS485 communication interface, using Modbus protocol

communication

RS485 interface, half duplex, optical isolation, Modbus-RTU protocol

Baud rates 1200, 2400, 4800, 9600, 19200 optional

Display method

LED or LCD (bright blue background light, backlight delay time adjustable)

Installation method

DIN35mm rail mounting

example

Model Number: PZ300-DE

Input: DC0-60V DC0-50A/0-75mV Shunt Access

Display mode: LCD display

Auxiliary power supply: AC/DC85-270V

Measurement parameters: DC voltage, DC current, DC power, DC power