As the saying goes, there is no rule, and there is no rule. Therefore, everything needs certain rules and guidelines. Today, the home of the decoration home network wants to introduce the standard of floor heating. The families in the northern area basically have floor heating, but only understand. The floor heating standard is a good choice for laying, in order to prevent errors and lead to a loss of quality experience. Let's take a look at the standard of floor heating. Floor heating standard - introduction to floor heating Floor heating is the abbreviation of floor radiant heating. English is Radiant Floor Heating. It uses the whole ground as the radiator. It heats the whole ground evenly through the heat medium in the radiation layer of the floor. It uses the ground's own heat storage and heat to radiate upward. Conducting the supremacy to achieve the purpose of heating. Water floor heating refers to a heating method that heats water to a certain temperature, transports it to the water pipe cooling network under the floor, and achieves the purpose of heating through the floor heating. The low-temperature ground heat medium forms a temperature gradient in the room from the sole to the head, which gives the person a warm feeling of warm head. The ground radiant heating conforms to the traditional Chinese medicine "temperature and cold" health theory, is currently the most comfortable heating method, and is also a symbol of modern life quality. Floor heating standard - introduction of floor heating operation process 1. Requirements for leveling: Before the construction of the floor heating project, the ground level is required, without any unevenness, sand and stone fragments, steel bars and so on. Therefore, it is required that the civil works should be used as a cement mortar leveling layer to clean the ground. The wire tube is only allowed to pass vertically through the floor heating layer. 2. Installation of the sub-catch: it should be perpendicular to the ground and firmly fixed to the wall. The height of the riser shall not be less than 150mm, not more than 700mm, and the installation position of each layer of the distributor shall be the same. 3. Laying of the insulation layer: laying polystyrene board in places where heat loss is not required, and adding aluminum foil. 4, the laying of cryogenic tubes: loop requirements: strictly in accordance with the system design plan construction, finished product protection, compaction steps. Pipe fixing: The heating pipe should be fixed, and the heating pipe is tied with the wire on the wire mesh laid on the surface of the heat insulation layer. 5. Installation and treatment of threaded casing: The pipe spacing is less than or equal to 10 cm or over the wall, or the expansion joint is installed with the threaded sleeve, and the wall sleeve is not less than 5 cm. 6, the requirements of the cover layer: backfilled bean stone concrete (fine stone inspection diameter ≤ 1.2 cm, pea stone application water rinse); according to thermal theory, the thickness of the cover layer and the medium will directly affect the heat dissipation of the bare tube, so cover The height of the layer is easily 2 to 3 cm above the tube. (Party A) Floor heating standard - introduction of floor heating standards 1. General regulations: design drawings and other technical documents are complete. The approved construction plan or construction organization and design have been technically delivered. Construction strength and machine tools can ensure normal construction. Temporary facilities such as construction site, construction water and electricity, and material storage sites can meet the construction needs. 2, before the construction of floor radiant heating, should understand the structure of the building, familiar with the design drawings. Coordination measures for construction plans and other types of work. The installer should be familiar with the general performance of the pipe, master the basic operating points, and strictly prohibit blind construction. 3. When installing the heating pipe, check the appearance of the material and remove dirt and debris inside and outside the pipe and pipe fittings. 4. During the installation process, paint, asphalt or other chemical solvents should be prevented from contaminating plastic pipes. 5. If the piping system is installed intermittently or finished, it should be blocked at any time. 6. The insulation layer should be laid on a flat basis. 7. According to the requirements of the design drawings, the piping should be carried out, and the heating pipes of the same passage should be kept horizontal. 8. The bending radius of the heating tube and the PEX tube should not be less than 5 times the outer diameter of the tube. 9. The heating pipe in the filling layer must not have a joint. 10. Use special tools to cut the pipe, the fracture should be flat, and the fracture surface should be perpendicular to the pipe spoke. The above is the introduction of the floor heating standard for the decoration home network Xiaobian. I don’t know how much you know about the floor heating laying specification after reading it. In Xiaobian’s view, the floor heating laying specification is very effective. The choice of floor heating environment allows us to get a better quality floor heating experience, allowing our floor heating to be laid in the right laying environment for a long service life. If you want to know more about the exciting content, please continue to pay attention to our decoration encyclopedia! More related wonderful reading: How to do floor heating? The benefits of floor heating Home floor heating basic classification family floor heating precautions Woven Polypropylene Covers,Paint Roller Covers,Polypropylene Roller Cover,Woven Polypropylene Roller Cover Ningbo Beilun Gelei Plastic Parts Co.,Ltd , https://www.paintwelltools.com