Chemical Industry Mass Flow Meter
Sealand is a professional supplier of Chemical Mass Flow Meter, Chemical Mass Flowmeter, Chemical Flowmeter, Chemical Flow Meter, Chemical Coriolis Meter, ATEX, IECEx & CE approved.
The meter can work with a pulse receiver(Count). The connection is as follows. The
resistance value is up to the cable length & the max. input pulse frequency of receiver.
Current 10mA is suitable for most receivers; however, you can reduce the resistance value
when the cable is long. The max. current could be 50mA. Please use the fixed frequency
output function to check if the cable length & resistance value is suitable.
Please check following items before operation, and operate according to relevant rules.
a) If the meter is damaged during shipment and installation;
d) If the meter is grounded properly.
Name of product specification Materials Steel factory / origin Today's price (yuan/ton) Yesterday's price (yuan/ton) Change (yuan/ton) Channel steel 10#*6mm Q235 Jiang Tian 3600-3610 3600-3610 constant Channel steel 16#12mm Q235 Jiang Tian 3600-3610 3600-3610 constant Channel steel 20#*12mm Q235 Jiang Tian 3700-3710 3700-3710 constant Angle Steel 50mm*50*5/6m Q235 Tong Gang 3550-3560 3550-3560 constant Angle Steel 80mm*80*8/6m Q345 Tong Gang 3550-3560 3550-3560 constant Angle Steel 100mm*100*10/9m Q235 Tong Gang 3600-3610 3600-3610 constant I-beam 16#12mm Q235 Haicheng 3700-3750 3700-3750 constant I-beam 20#12mm Q235 Haicheng 3700-3750 3700-3750 constant I-beam 25#12mm Q235 Haicheng 3700-3750 3700-3750 constant H-shaped steel 100*100**6*8 Q235/SS400 Lai Gang 4350-4360 4350-4360 constant H-shaped steel 150*150*7*10 Q235/SS400 Lai Gang 4000-4010 4000-4010 constant H-shaped steel 300*300*10*15 Q235/SS400 Ma Gang 4130-4140 4130-4140 constant H-shaped steel 400*400*13*21 Q235/SS400 Ma Gang 4300-4310 4300-4310 constant H-shaped steel 500*200*10*16 Q235/SS400 Ma Gang 4030-4040 4030-4040 constant H-shaped steel 700*300*13*24 Q235/SS400 Ma Gang 4300-4310 4300-4310 constant
b) If the voltage is same as marked on nameplate;
c) If the fuse is correct;
e) If the Meter SN on the nameplate of sensor and transmitter are the same.
If everything is fine, please open all valves, make the pipeline full of liquid and then power on
the meter for warm-up for 20min before operation. Finally, conduct zero calibration after first
start, and shall do it again if the meter is moved to another site.
Preparation for zero calibration:
a) Power on the meter for approximately 20min for warm-up;
b) Run the process fluid through the sensor until the sensor temperature reaches the normal
process operating temperature.
c) Close the shutoff valve downstream from the sensor.
d) Ensure that the sensor is filled with fluid and the process flow has completely stopped.
Chemical Mass Flow Meter, Chemical Mass Flowmeter, Chemical Flowmeter, Chemical Flow Meter, Chemical Coriolis Meter